Furnace water regulator KR-506

Product Profile】

KR-506 is a multi-function furnace water treatment agent, operating pressure less than 16 MPa boiler system can be used. The product can make the boiler achieve high concentration / low discharge rate, in which the medicament components can effectively prevent scale, eliminate scale, suppress boiler water foam, form passivation film on the pipe wall, so as to achieve the management purpose of scale inhibition, anticorrosion, reduce sewage discharge and improve steam quality.Physical and chemical properties】

Appearance:  Transparent colorless or yellowish

Specific gravity: 1.00.±0.03 at 20℃

pH value:  ≥12at 20℃

 P-alkalinity:  ³700mg/L(以 CaCO3 计),1%w/v。

 Water-solubility: 100%

 Freezing Point:  -2℃

Product characteristics】

Less increase in total dissolved solids in boiler water.

The medicament applies to all types of boiler systems MPa pressure £16.0.

Complete replacement of trisodium phosphate.

It has the function of preventing scale, removing scale and dispersing water slag.

Chelating effect on iron and copper plasma.

Allow boilers to operate at a minimum discharge rate of 0.3 per cent.

Inhibit blistering of furnace water and reduce steam pollution caused by mechanical carrying.

Direct use, no dilution.

Inorganic phosphorus is used as indicator parameter to calculate the concentration multiple of boiler water and eliminate the boiler water.

Residual hardness.

 Method of dosing】

According to the content of phosphate pH、 furnace water, and affected by water quality and sewage discharge, the specific dosage should meet the requirements of water vapor quality index, see "Table 1-water vapor quality Standard ".

Dosing is usually measured in recharge water, usually between 5-8 mg/L.

Add the drug directly to the drum.

Notes】

The medicament is alkaline, corrosive and irritating to skin and eyes, and should be handled and used carefully.

Packing and Storage

 20kg, 25kg, 200kg or 1000kg plastic packing drum.

Storage should be sealed to avoid sunshine and contact with high temperature, avoid freezing.

In the case of airtight, the warranty period is 1 year.

The medicine after opening should be used up within two weeks.

File 1-Water vapor quality standard

 

Boiler

drum

pressure 

MPa

PH

Phosphoric acid

silica

Chloride chloride

Direct conductivity(25℃)

(25℃)

mg/L

mg/L

mg/L

μS/cm

5.9~10.0

9.0~10.5

2~10

≤2.0

-

≤50

10.1~12.6

9.0~10.0

2~6

≤2.0

-

≤30

12.7~15.6

9.0~9.7

≤3

≤0.45

≤5

≤35

 

①The GB/T 12145-2016 specification value is £1.5, because the furnace water regulator has good foam and corrosion resistance. In order to improve the concentration rate of furnace water and reduce the discharge, we raise the chloride ion control standard to 5 mg/L under the premise of ensuring the steam quality and preventing corrosion.

②The GB/T 12145-2016 specification value is £20, because the furnace water regulator has good foam and corrosion resistance. In order to improve the concentration rate of furnace water and reduce the discharge, we raise the chloride ion control standard to 35 mS/cm under the premise of ensuring the steam quality and preventing corrosion.




label

0
  • 1611713825208387.png

    Kelun Chinese station

    ewm2.png

    Kerun International Station

    • Textile Auxiliary BranchPrinting and dyeing auxiliaries Division

      f01.png Jimo,Qingdao,China

      f02.png 0086-532-86538266

    • Water Treatment Branch biological water treatment Division

      f01.png Jimo,Qingdao,China

      f02.png 0086-532-86538255

    • Leather Auxiliary BranchLeather auxiliaries Division

      f01.png Jimo,Qingdao,China

      f02.png 0086-532- 86538288